Technical Characteristics:
Analog Inputs:
Number of channels: 7 voltage inputs, 1 input for PT100, 2 inputs for 10K thermistor
Input ranges: 100 mV, 1.0 V, 2.0 V, 5.0 V
Accuracy: 0.1% F.S., 5 V range (-40 to 60°C)
Sample rate: 1 KHz maximum
Resolution: 12 bit

Digital Inputs/Outputs:
Frequency inputs: 3 counters, 16-bit each independent of processor
Maximum count rate: 10 KHz
Input modes: 2 high speed inputs for sine wave or square wave anemometers, 1 input for contact closure rain gauges
Alarm outputs: 2 open collector @ 2 A max for high or low threshold events

Serial Channels:
RS232C port: 1 port with hardware and software handshaking, baud rates 110 bps to 56 Kbps, 9 pin d-sub connector

Processor Functions:
Configuration: Stored in non-volatile EEPROM
Standard data memory: 128 KB SRAM with battery backup
Optional data memory: 256 KB, 512 KB
Calendar clock: Date, time, leap year, accuracy ±30 sec/month
Backup battery: For memory and clock, 7 year life

Power Requirements:
Input voltage: +7 to 40 Vdc
Operating current: < 55 mA @ 12 Vdc
Optional sleep mode: .5 mA @ 12 Vdc
Input protection: Fuse, surge protection, reverse polarity, and over-voltage
Supply sources: Battery, solar power, unregulated DC

Environmental Characteristics:
Operating temperature: -40 to 60°C
Humidity: 0-90% RH non-condensing

Construction:
Circuit boards: Approx 90% surface mounted components, internal power and ground planes, and built-in EMI and ESD protection
Lightning protection: Minimum 2 stages of protection devices on all signal and power lines when connected to an external earth ground. Includes MOVs on wind sensor input
Connections: User interface PCB 30-pin screw terminal, ground lug
Desktop enclosure: 7" x 7" x 3-3/4" aluminum

Applications:
The 195-WS-16 Data Logger is designed specifically for collecting meteorological data. It has a versatile processor that can be used in systems from portable stations to networks. It is a complete package with sensor interfaces, data processing and logging, communications interfaces, and software for display, reporting, and data retrieval via a standard RS232 cable. Two independent user programmable alarms are supplied.

Make the Download of the Datasheet


Signal Conditioners Series 130-200

Technical Characteristics:
Input power: 9 to 30 Vdc, 1.5 W typical, 2.5 W maximum
Accuracy: including linearity and hysteresis ±0.1% @ 25°C
Stability: Temp <±0.025%/°C
Isolation: 1800 Vdc between input, output and power
Dimensions: 4.4" (112 mm) H x 3" (76 mm) D x 0.5" (12 mm) W
Operating temperature range: 0 to 55°C (32 to 131F)
Storage temperature range: -25 to +70°C (-13 to +158F)
Operating humidity: 15 to 95% @ 45°C
Voltage output: 0-5 V, 0-10 V (selectable)
Impedance: < 10 ohms
Drive: 10 mA, max
Current output: 0-1 mA, 4-20 mA, 0-20 mA (selectable)
Impedance: > 100 Kohm
Compliance: 0-1 mA: 7.5 V, max (7.5K ohm) 4-20 mA: 12 V, max (600 ohm) 0-20 mA: 12 V, max (600 ohm)
Input: Each conditioner supports a wide range of specific inputs that support most of the Novalynx sensors
Mounting: Horizontal din rail mounting is recommended
Size: 3.54" W x 4.34" D x .50" H

Applications:
The 130-200 Series Signal Conditioners is a full line of field configurable conditioners useful for transmitting process control setpoints to remote PID controllers or interfacing position sensors to data acquisition and control systems.

Make the Download of the Datasheet


Datalogger – Comunication
Spread Spectrum Radio model 140-400

Technical Characteristics:
General:
Frequency: 902-928 MHz
Spreading spectrum type: Frequency hopping, direct FM
Serial data interface: RS232/422/485
I/O data rage: Software selectable 1,200-57,000 bps

Power Requirements:
Supply voltage: 7-18 Vdc
Transmit current: 200 mA
Receive current: 70 mA
Power down current: < 1 mA

Physical Properties:
Enclosure type: Extruded aluminum, black anodized
Enclosure size: 2.75" x 5.50" x 1.124" (7.90 x 13.90 x 3.80 cm)
Weight: 7.1 oz (200 g)
Operating temperature: -40° to +85°C

Antenna:
Type: 1/2 wave dipole whip
Gain: 2.1 dB
Length: 6.75" (17.1 cm)
Impedance: 50 ohms unbalanced

Performance:
Indoor/Urban range: Up to 1,500' (457 m)
Outdoor LOS range: Up to 7 mi (11 km) with dipole, up to 20 mi (32 km) with hi-gain

Applications:
The Model 140-400 Spread Spectrum Radio was designed to provide end users with an easy to install wireless serial communication link. Used with the WS-16 Data Logger and a high-gain antenna, it provides data communication up to 20 miles. When configured as an addressable unit, it is suitable for use in a network of up to four weather stations.

Make the Download of the Datasheet


Potentiometric Recorders Series 300-8730

Technical Characteristics:
Recorder type: Self-balancing
Balancing speed: 2.1 seconds (60 Hz) or 2.5 seconds (50 Hz) for full-scale deflection
Measuring system: Potentiometric
Input range: 0-10 mV or 0-1 Vdc standard
Input impedance: Approx 100K ohms
Accuracy: ± 0.5% of measuring range
Dead band: 0.1% of full-scale
Recording system:
   *Continuous writing: 1 or 2 capillary pens
   *Dotting: 6, 12, or 24 points
   *Dotting interval: 5 seconds (60 Hz), 6 seconds (50 Hz)
Chart type: Fanfold
Chart size: 7.9" W x 66' L (200 mm x 20 m), 7.1" (180 mm) calibrated width
Chart speed: Selectable: 12.5, 25, 50, or 100 mm/hr standard, others on special order
Illumination: Fluorescent lamp
Operating temperature: -10° to +50°C
Input voltage: 115 or 230 Vac, 50/60 Hz
Power: 24 VA (1-pen and dotting), 30 VA (2-pen)
Size: 11.3" W x 11.3" H x 12.6" D (288 x 288 x 300 mm)
Weight/shipping: 30 lbs/40 lbs (13.6 kg/19 kg)

Applications:
The 300-8730 Series Potentiometric Recorders are a versatile line of precision, self-balancing potentiometric strip chart recorders. These recorders incorporate a variety of features designed to meet the demands of numerous applications. The 7-inch wide chart provides excellent data resolution in most situations.

Make the Download of the Datasheet






Click to print
this page
Click to print this page


HOME      THE COMPANY      PRODUCTS      AREAS OF ACTIVITY      SERVICES      PARTNERSHIPS      CONTACTS      SUPPORT

All rights reserved
This site is best viewed in 1024 x 768 resolution