Datalogger model 195-WS-16
Technical Characteristics:
Analog Inputs:

Number of channels: 7 voltage inputs, 1 input for PT100, 2 inputs for 10K thermistor

Input ranges: 100 mV, 1.0 V, 2.0 V, 5.0 V

Accuracy: 0.1% F.S., 5 V range (-40 to 60°C)

Sample rate: 1 KHz maximum

Resolution: 12 bit
Digital Inputs/Outputs:

Frequency inputs: 3 counters, 16-bit each independent of processor

Maximum count rate: 10 KHz

Input modes: 2 high speed inputs for sine wave or square wave anemometers, 1 input for contact closure rain gauges

Alarm outputs: 2 open collector @ 2 A max for high or low threshold events
Serial Channels:

RS232C port: 1 port with hardware and software handshaking, baud rates 110 bps to 56 Kbps, 9 pin d-sub connector
Processor Functions:

Configuration: Stored in non-volatile EEPROM

Standard data memory: 128 KB SRAM with battery backup

Optional data memory: 256 KB, 512 KB

Calendar clock: Date, time, leap year, accuracy ±30 sec/month

Backup battery: For memory and clock, 7 year life
Power Requirements:

Input voltage: +7 to 40 Vdc

Operating current: < 55 mA @ 12 Vdc

Optional sleep mode: .5 mA @ 12 Vdc

Input protection: Fuse, surge protection, reverse polarity, and over-voltage

Supply sources: Battery, solar power, unregulated DC
Environmental Characteristics:

Operating temperature: -40 to 60°C

Humidity: 0-90% RH non-condensing
Construction:

Circuit boards: Approx 90% surface mounted components, internal power and ground planes, and built-in EMI and ESD protection

Lightning protection: Minimum 2 stages of protection devices on all signal and power lines when connected to an external earth ground. Includes MOVs on wind sensor input

Connections: User interface PCB 30-pin screw terminal, ground lug

Desktop enclosure: 7" x 7" x 3-3/4" aluminum
Applications:

The 195-WS-16 Data Logger is designed specifically for collecting meteorological data. It has a versatile processor that can be used in systems from portable stations to networks. It is a complete package with sensor interfaces, data processing and logging, communications interfaces, and software for display, reporting, and data retrieval via a standard RS232 cable. Two independent user programmable alarms are supplied.
Make the Download of the Datasheet
Signal Conditioners Series 130-200
Technical Characteristics:

Input power: 9 to 30 Vdc, 1.5 W typical, 2.5 W maximum

Accuracy: including linearity and hysteresis ±0.1% @ 25°C

Stability: Temp <±0.025%/°C

Isolation: 1800 Vdc between input, output and power

Dimensions: 4.4" (112 mm) H x 3" (76 mm) D x 0.5" (12 mm) W

Operating temperature range: 0 to 55°C (32 to 131F)

Storage temperature range: -25 to +70°C (-13 to +158F)

Operating humidity: 15 to 95% @ 45°C

Voltage output: 0-5 V, 0-10 V (selectable)

Impedance: < 10 ohms

Drive: 10 mA, max

Current output: 0-1 mA, 4-20 mA, 0-20 mA (selectable)

Impedance: > 100 Kohm

Compliance: 0-1 mA: 7.5 V, max (7.5K ohm) 4-20 mA: 12 V, max (600 ohm) 0-20 mA: 12 V, max (600 ohm)

Input: Each conditioner supports a wide range of specific inputs that support most of the Novalynx sensors

Mounting: Horizontal din rail mounting is recommended

Size: 3.54" W x 4.34" D x .50" H
Applications:

The 130-200 Series Signal Conditioners is a full line of field configurable conditioners useful for transmitting process control setpoints to remote PID controllers or interfacing position sensors to data acquisition and control systems.
Make the Download of the Datasheet
Datalogger – Comunication
Spread Spectrum Radio model 140-400
Technical Characteristics:
General:

Frequency: 902-928 MHz

Spreading spectrum type: Frequency hopping, direct FM

Serial data interface: RS232/422/485

I/O data rage: Software selectable 1,200-57,000 bps
Power Requirements:

Supply voltage: 7-18 Vdc

Transmit current: 200 mA

Receive current: 70 mA

Power down current: < 1 mA
Physical Properties:

Enclosure type: Extruded aluminum, black anodized

Enclosure size: 2.75" x 5.50" x 1.124" (7.90 x 13.90 x 3.80 cm)

Weight: 7.1 oz (200 g)

Operating temperature: -40° to +85°C
Antenna:

Type: 1/2 wave dipole whip

Gain: 2.1 dB

Length: 6.75" (17.1 cm)

Impedance: 50 ohms unbalanced
Performance:

Indoor/Urban range: Up to 1,500' (457 m)

Outdoor LOS range: Up to 7 mi (11 km) with dipole, up to 20 mi (32 km) with hi-gain
Applications:

The Model 140-400 Spread Spectrum Radio was designed to provide end users with an easy to install wireless serial communication link. Used with the WS-16 Data Logger and a high-gain antenna, it provides data communication up to 20 miles. When configured as an addressable unit, it is suitable for use in a network of up to four weather stations.
Make the Download of the Datasheet
Potentiometric Recorders Series 300-8730
Technical Characteristics:

Recorder type: Self-balancing

Balancing speed: 2.1 seconds (60 Hz) or 2.5 seconds (50 Hz) for full-scale deflection

Measuring system: Potentiometric

Input range: 0-10 mV or 0-1 Vdc standard

Input impedance: Approx 100K ohms

Accuracy: ± 0.5% of measuring range

Dead band: 0.1% of full-scale

Recording system:
   *Continuous writing: 1 or 2 capillary pens
   *Dotting: 6, 12, or 24 points
   *Dotting interval: 5 seconds (60 Hz), 6 seconds (50 Hz)

Chart type: Fanfold

Chart size: 7.9" W x 66' L (200 mm x 20 m), 7.1" (180 mm) calibrated width

Chart speed: Selectable: 12.5, 25, 50, or 100 mm/hr standard, others on special order

Illumination: Fluorescent lamp

Operating temperature: -10° to +50°C

Input voltage: 115 or 230 Vac, 50/60 Hz

Power: 24 VA (1-pen and dotting), 30 VA (2-pen)

Size: 11.3" W x 11.3" H x 12.6" D (288 x 288 x 300 mm)

Weight/shipping: 30 lbs/40 lbs (13.6 kg/19 kg)
Applications:

The 300-8730 Series Potentiometric Recorders are a versatile line of precision, self-balancing potentiometric strip chart recorders. These recorders incorporate a variety of features designed to meet the demands of numerous applications. The 7-inch wide chart provides excellent data resolution in most situations.
Make the Download of the Datasheet